Nuicon

EE260 Humidity and Temperature Probe: Heated Meteorological Sensor

In meteorology, condensation and freezing rain are data killers. Standard probes get covered in dew or ice, flatlining at 100% RH for hours. The Nuicon EE260 Humidity and Temperature Probe is engineered for continuous high-accuracy monitoring in the harshest outdoor climates. Featuring a dual heating system, it keeps both the sensing element and the probe body warm, preventing condensation and icing even in freezing fog.

EE260 Humidity & Temperature Probe – Highlights

Continuous Operation: Accurate humidity measurement even in fog and high moisture.

Dual Heating System

Prevents condensation and ice for reliable readings.

RS485 Modbus Output

Direct transmission of dew point and related values.

Wide Temperature Range

Operates from −60°C to +60°C

Technical Specifications

  • Humidity Range: 0…100 % RH (heated)
  • Humidity Accuracy: ±1.3 % RH (typical, for 5…40 °C and RH ≤90 %)
  • Temperature Range: -60…+60 °C (-76…+140 °F)
  • Output: RS485 (Modbus RTU)
  • Supply Voltage: 7–30 V DC
  • Protection: IP67 / Stainless Steel probe

 

CDS201 - CO2 Sensor - Nuicon
CDS201 - CO2 Sensor - Nuicon

Where to Use the EE260 Probe

  • Airports: Critical for detecting freezing fog and runway icing conditions using the EE260 Humidity and Temperature Probe.
  • Road Weather: Monitors highways for black ice formation to trigger salt spreader trucks.
  • Offshore Platforms: Withstands salt spray and high humidity without corrosion or drift.
  • Wind Turbines: Prevents ice throw by detecting icing conditions on nacelles early.

Why Choose Nuicon?

Meteorology Experts

We understand the physics of heated probes and help you integrate the separate temperature sensor.

Project Support

We supply the correct radiation shields and mounting clamps.

Rapid Delivery

We stock these units in Bengaluru for urgent HVAC retrofits.

Frequently Asked Questions

Yes. Because the probe is warm, it cannot measure ambient temperature. You must use a separate temperature probe (like the EE060 or a PT100) alongside the EE260.

It measures the dew point (which is independent of temperature) and back-calculates relative humidity using the ambient temperature from the separate probe.

Yes, via Modbus commands, but we recommend keeping it active for freeze protection.

CDS201 - CO2 Sensor - Nuicon

Explore Other Weather Probes

EE08 High Precision

The unheated version for standard meteorological stations.

EE211 Heated Transmitter

Similar heating tech but designed for indoor high-humidity storage.

Omniport 30 Handheld

Rugged meter for field calibration of weather stations.

Our Happy Faces

Don't Let Ice Stop Your Data.

Get continuous meteorological accuracy with the EE260. Shop from Nuicon.

Have A Question?

Have A Question?

Get In Touch

First