Nuicon

EE451 Wall Mounted Temperature Sensor

Efficient buildings adapt to the weather. The Nuicon EE451 Wall Mounted Temperature Sensor provides the critical outdoor temperature data your BMS needs to adjust heating and cooling loads proactively. Housed in a robust IP65 enclosure, it withstands rain, dust, and industrial washdowns, making it the reliable choice for outdoor installation and warehouses.

EE451 Wall Mounted Temperature Sensor – Key Benefits

IP65 Weatherproof Enclosure: Durable polycarbonate housing protects against moisture and dust.

Easy Installation

Snap-shut cover and spacious terminals simplify wiring.

Universal Outputs

Passive (Pt100, NTC, Ni) or active 0–10 V / 4–20 mA options.

Optional LCD Display

Clear local temperature indication for quick checks.

Technical Specifications

  • Range (Active): -40…+70 °C (Configurable)
  • Range (Passive): Sensor dependent (e.g., -40…+110 °C)
  • Accuracy: ±0.3 °C (Active) / Class A (Passive)
  • Output: 0–10 V / 4–20 mA / Modbus RTU / Passive
  • Supply: 15–35 V DC (Active)
  • Protection: IP65 / NEMA 4X
CDS201 - CO2 Sensor - Nuicon
CDS201 - CO2 Sensor - Nuicon

Where to Use the EE451 Sensor

  • Weather Compensation: Mounted on the north wall, it drives the building’s heating curve for maximum energy efficiency.
  • Cold Rooms: Survives the humidity and washdowns in refrigerated storage areas using the EE451 Wall Mounted Temperature Sensor.
  • Warehouses: Monitors ambient temperature in large industrial halls to protect inventory.
  • Greenhouses: Controls ventilation based on external temperature conditions.

Why Choose Nuicon?

Installation Advice

We help you position the sensor correctly (e.g., North side, away from vents) for accurate data.

Sun Shields

We supply the HA010502 radiation shield to protect the sensor from direct sunlight heat spikes.

Fast Delivery

Stocked in Bengaluru for immediate dispatch to your site.

Frequently Asked Questions

Yes. If the EE451 Wall Mounted Temperature Sensor is exposed to direct sunlight, a radiation shield is mandatory to prevent false high readings.

 Absolutely. It is perfect for industrial rooms, factories, or damp basements where a standard office sensor would fail.

 Yes. We offer every standard passive resistance curve (Pt100, NTC, etc.) to match any HVAC controller.

CDS201 - CO2 Sensor - Nuicon

Explore Other Temp Sensors

EE431 Duct Sensor

The version with a probe for air ducts or water pipes.

EE441 Strap-On

Measures pipe temperature from the outside surface.

EE10 Room Sensor

The aesthetic IP30 version for indoor offices and hotels.

Our Happy Faces

Weather-Proof Your Controls.

Get accurate outdoor data with the EE451.

Have A Question?

Have A Question?

Get In Touch

First